- Stock: In Stock
- Model: 22313
Yokogawa Y/15A-LS4/NAS-FB//SSB/TP-S/EPF/CAL-B
Yokogawa Y/15A Pneumatic Differential Pressure Transmitter
Sku: 22313
The Yokogawa Pneumatic differential pressure model Y / 15A Transmitters measure differential pressure in sections from 1.25 to 6.2 kPa at static pressure at 3.5 MPa. The instruments transmit a ratio of 20 to 100 kPa. signal to remote pneumatic receivers.
Time-Proven Pneumatic Differential Pressure Transmitter Design.
Trouble-Free Construction.
Excellent Performance.
Easy to Calibrate.
Wide Range Capability.
Versatile Applications Capability for Flow, Liquid Level, and Density Measurements
Air Supply Pressure: 140 kPa, 1.4 kgf/cm2 or bar, 1.4 bar, or 20 psi.
Air Consumption: 0.5 m3/h at 0°C, 101.3 kPa (1.033 kgf/cm2} absolute (0.3 scfm).
Ambient Operating Temperature Range: -40 to 120°C (-40 to 250°F).
Process Temperature Limits: -40 and 120°C (-40 and 250°F) at capsule.
Mounting: Bracket for nominal 50 mm (2 inches) horizontal or vertical pipe. Transmitter must be mounted with capsule faces vertical.
Air Connection: Tapped for JIS R1/4 or 1/4 NPT, whichever specified.
Process Connections: JIS Rc1/2, Rc1/4, 1/2 NPT, or 1/4 NPT female, whichever specified.